BER is transitioning to a new database management system. Data displaying from the ISL was last updated as of 8 am CST on June 3, 2021. Should you have any immediate data needs, please submit a Kansas Open Records Act (KORA) request. We apologize for the inconvenience.
Kansas Department of Health and Environment
Bureau of Environmental Remediation
Identified Sites List Information
| Project Code: | C208773100 | Site Status: | Active |
| Site Name: | Four Seasons Dry Cleaner - 8947 W Central Ave |
| CERCLIS Number: | |
| Other Names: | |
| Address: | 8947 W Central Ave | City: | Wichita |
| Zip Code: | 67212 |
| County: | SG | River Basin: | |
| Latitude: | 37.69278 | Longitude: | -97.44629 |
| Program Name: | BER - Dry Cleaner Remediation | Project Manager: | Chris Wierman, P.G. |
| Contaminants: | VOC |
Environmental Use Control In Place ?
No
|
We are currently experiencing technical difficulties with requests for some documents. If an attempt to download an individual document from the “Documents/Photos Available” link does not return the expected results, please contact the Project Manager associated with the Identified Site or the Remedial Section at 785-296-1660. We are working to resolve this problem as quickly as possible and apologize for any inconvenience this may cause.
Documents/Photos Available
(Opens in New Window) |
|
|
Site Narrative:
In 2009, the KDHE Site Assessment Program conducted a Unified Focused Assessment (UFA) of the former Standard Products radium dial property at 7920 West Kellogg in Wichita, Kansas. Samples collected during the UFA contained tetrachloroethylene (PCE). The former Standard Products site was referred for additional investigation to determine the source of the PCE.
In 2013, a Site Evaluation at the former Standard Products site concluded that the PCE was emanating from an upgradient source. In 2014, samples from six private domestic wells and from direct push borings in the upgradient direction from the former Standard Products site were collected. The Site Assessment program also conducted a directory search to identify potential sources which operated in the upgradient area. Direct push sampling and the directory search identified the former Four Seasons Dry Cleaners at 8947 W. Central Ave. and the former Best Cleaners at 9334 W. Central as potential sources of the contamination. Analytical results identified the former Four Seasons as a source of PCE contamination.
The site was transferred to the Kansas Dry Cleaning Program in 2014 for additional investigation, corrective action and collect additional samples from private wells. A total of 222 samples were collected from private wells.
The Dry Cleaning Program compared the analytical results from the domestic well sampling to the EPA Maximum Contaminant Level (MCL) and the EPA Removal Management Level (RML) concentrations to determine immediate risk to the residents. The MCL is a drinking water standard calculated for long-term ingestion of drinking water. The RML is a shorter-term risk based screening value used to make risk-based decisions for the removal of the risk. Domestic wells with sample results greater than the RMLs were equipped with a point-of-entry whole-house carbon treatment system to reduce the risk of exposure to contaminated water. Residences with domestic well sample results greater than the MCL but less than the RML were provided with bottled water for drinking and cooking. The City of Wichita municipal water supply water mains were extended to connect residences in the AoC to the municipal water supply.
Vapor intrusion investigations were completed at a middle school located in close proximity to the plume; an apartment complex immediately down-gradient of the former Four Seasons dry cleaners; and nine single-family residences. All vapor intrusion results were below the KDHE action levels.
Additional source assessment was completed in 2017 & 2018 to better delineate the location of the contamination. Based on the data collected, additional monitoring wells were installed and work was awarded for an air sparge / soil vapor extraction system design using a cut-off trench.
Vapor Intrusion Assessment has been completed in the AOC to assess the risk of vapor intrusion from subsurface contamination.
The AS/SVE System has been installed and is operational. Monitoring is currently underway to determine the effectiveness of the remedy. |
|
|
Legal Description
|
|
|
Actions Completed
| INTERIM ACTION | Provide Alternative Water Supply | 04/23/2014 | 08/15/2017 |
| INVESTIGATION | Comprehensive Investigation | 11/16/2016 | 06/13/2018 |
| INVESTIGATION | Contamination Assessment | 02/11/2019 | 03/22/2019 |
| REMEDIAL DESIGN/ACTION | Remedial Action | 05/01/2018 | 02/26/2021 |
| MONITORING | O&M/Performance Monitoring | 02/01/2020 | 05/28/2021 |
| MONITORING | Long Term Monitoring | 10/15/2014 | 06/04/2021 |
| INVESTIGATION | Supplemental Investigation | 07/16/2021 | 04/12/2022 |
| MONITORING | O&M/Performance Monitoring | 06/21/2021 | 11/03/2023 |
| MONITORING | O&M/Performance Monitoring | 01/01/2022 | 01/29/2025 |
|
|
|
Actions Underway
| MASTER PROJECT | Master Project Details | 04/23/2014 | |
| MONITORING | O&M/Performance Monitoring | 07/06/2023 | |
| MONITORING | O&M/Performance Monitoring | 06/26/2024 | |
| MONITORING | O&M/Performance Monitoring | 03/23/2026 | |
|
|
|
Actions Proposed
|
No Actions Proposed Information Found
|
|
|
|
Map of Identified Site ((One-mile radius circle around selected site))
Click here for interactive map
 |