BER is transitioning to a new database management system. Data displaying from the ISL was last updated as of 8 am CST on June 3, 2021. Should you have any immediate data needs, please submit a Kansas Open Records Act (KORA) request. We apologize for the inconvenience.
Kansas Department of Health and Environment
Bureau of Environmental Remediation
Identified Sites List Information
Project Code: | C508570354 | Site Status: | Active |
Site Name: | EXPRESS CLEANERS - SALINA |
CERCLIS Number: | |
Other Names: | |
Address: | 540 S SANTA FE | City: | SALINA |
Zip Code: | 67401 |
County: | SA | River Basin: | Smoky Hills - Saline |
Latitude: | 38.8309 | Longitude: | -97.61065 |
Program Name: | BER - Dry Cleaner Remediation | Project Manager: | Michael Casanova |
Contaminants: | VOC |
Environmental Use Control In Place ?
No
|
We are currently experiencing technical difficulties with requests for some documents. If an attempt to download an individual document from the “Documents/Photos Available” link does not return the expected results, please contact the Project Manager associated with the Identified Site or the Remedial Section at 785-296-1660. We are working to resolve this problem as quickly as possible and apologize for any inconvenience this may cause.
Documents/Photos Available
(Opens in New Window) |
|
Site Narrative:
The result of an ESA during 1997 and 1998, Express Cleaners was identified as the primary source for PCE in three nearby PWS wells. The site is currently owned by the Salina Regional Medical Center. An ESA was completed on January 12, 1999. A SVE system was installed. It was started up on November 27, 2001. It was shut down in April 2002 moved in May 2002 and restarted in July 2002. A source investigation was conducted in May of 2004.
Review of field data collected during O&M visits indicates that VOC concentrations being removed by SVE system have begun to reach an asymptotic level. To check, KDHE conducted a rebound study during December 2005, January and February 2006. The system was shut down with the exception of the horizontal lines beneath the Salina Regional Health Center Building. During the O&M visits, the system was restarted temporarily to take readings and determine if buildup of VOC occurred. Results of the rebound study showed there was little rebound of VOC concentrations while the system was down.
KDHE removed the remediation trailer and abandoned the lines in place. Groundwater monitoring indicates that a secondary souce exists along the sanitary sewer beneath Santa Fe.
KDHE has conducted long term monitoring since 2006. |
|
Legal Description
14 | 03W | 13 | | SW of the NW of the SW |
14 | 03W | 13 | | SW of the NW of the SW |
14 | 03W | 13 | | SW of the NW of the SW |
14 | 03W | 13 | | SW of the NW of the SW |
|
|
Actions Completed
MONITORING | Long Term Monitoring | | |
MONITORING | Long Term Monitoring | 09/17/2021 | |
EVALUATION OF REMEDIAL ALTERNATIVES | Feasibility Study | 09/23/1998 | 09/23/1998 |
ASSESSMENT | Expanded Site Assessment | 01/12/1999 | 01/12/1999 |
REMEDIAL DESIGN/ACTION | Corrective Action Plan | 08/14/2000 | 08/14/2000 |
REMEDIAL DESIGN/ACTION | Corrective Action Report | 09/12/2002 | 09/12/2002 |
MONITORING | O&M/Performance Monitoring | 01/19/2004 | 01/19/2004 |
INVESTIGATION | Source Investigation | 03/22/2004 | 10/01/2004 |
REMEDIAL DESIGN/ACTION | Corrective Action | 12/21/2001 | 06/23/2008 |
MONITORING | Long Term Monitoring | 06/01/2006 | 10/02/2013 |
MONITORING | Long Term Monitoring | 02/13/2018 | 02/13/2018 |
MONITORING | Long Term Monitoring | 02/14/2018 | 02/15/2018 |
MONITORING | Long Term Monitoring | 04/24/2019 | 06/18/2019 |
MONITORING | Long Term Monitoring | 11/27/2001 | 02/18/2021 |
|
|
Actions Underway
MASTER PROJECT | Master Project Details | 09/23/1998 | |
|
|
Actions Proposed
No Actions Proposed Information Found
|
|
|
Map of Identified Site ((One-mile radius circle around selected site))
Click here for interactive map
![ISL Classes](images/ISLClasses.bmp) |