BER is transitioning to a new database management system. Data displaying from the ISL was last updated as of 8 am CST on June 3, 2021. Should you have any immediate data needs, please submit a Kansas Open Records Act (KORA) request. We apologize for the inconvenience.

Kansas Department of Health and Environment
Bureau of Environmental Remediation
Identified Sites List Information

Project Code: C208772045Site Status:Transferred out of Bureau
Site Name: AIR CAPITOL DIAL (CURRENT)
CERCLIS Number:
Other Names:
Address: 220 NORTH VINECity:WICHITA
Zip Code:
County: SGRiver Basin:
Latitude: 37.68667Longitude:-97.36112
Program Name: BER - Site AssessmentProject Manager:
Contaminants: Radionuclides|VOC

Environmental Use Control In Place ?   No
We are currently experiencing technical difficulties with requests for some documents. If an attempt to download an individual document from the “Documents/Photos Available” link does not return the expected results, please contact the Project Manager associated with the Identified Site or the Remedial Section at 785-296-1660. We are working to resolve this problem as quickly as possible and apologize for any inconvenience this may cause.
Documents/Photos Available
(Opens in New Window)
 

Site Narrative:
The volatile organic compounds (VOC) analysis indicated trace amounts of tetrachloroethylene in samples GW-2, GW-3, and GW-4. The maximum detection was 1.2 µg/L in GW-4. This sample was located in a suspected upgradient direction. It does not appear that the PCE detections are attributable to releases from the Air Capital Dial. The PCE site will be identified as the West 2nd and Vine Street site for a future Site Reconnaissance and Evaluation (SRE) investigation. Metals were not significantly detected above background.

Radium-226 was detected in ground water at a maximum of 0.1 pCi/L in both GW-1 (background) and GW-3 (on-site). Since the background detection was 0.1 pCi/L, and the Maximum Contaminant Level (MCL) is 5 pCi/L above background, a significant release of radium-226 to ground water above background does not appear to be present at the site.

Elevated gamma radiation was detected in Soil #3 with a maximum screening level of 74 µR/hr. Soil #3 indicated radium (Ra-226) at 2.8 pCi/g by laboratory analysis. While the screening sample was elevated above background (8 µR/hr), this is below the EPA screening criteria of 5 pCi/g.

A significant release of VOCs and metals is not present in shallow ground water at the Air Capital Dial site. Radium-226 was detected below current screening levels, and it appears from the SRE data that an extensive area of exterior radiation is not present at the site. KDHE/BAR may conduct or direct the licensee to conduct a more detailed scoping survey to determine if any other contaminated areas are present within the interior of the building. Additional compliance issues for the interior of the facility will be conducted under KDHE/BAR lead regarding the Radioactive Materials License.
 

Legal Description
TownshipRangeSectionDescription
No Legal Description Information Found
 

Actions Completed
Activity TypeActivityStartCompleted
ASSESSMENTInitial Site Screening (ISS)09/30/200509/30/2005
ASSESSMENTSite Reconnaissance and Evaluation06/15/200606/15/2006
MASTER PROJECTMaster Project Details09/30/200506/26/2006
TRANSFERTransfer Out of Bureau06/26/200606/26/2006
 

Actions Underway
Activity TypeActivityStartCompleted
No Actions Underway Information Found
 

Actions Proposed
Activity TypeActivityStartCompleted
No Actions Proposed Information Found
 

Map of Identified Site
((One-mile radius circle around selected site))